Features
Man-Machine Interface,PLC Programmable Control Operations
Module Designation, change different operational pan which can pre-spraying granulating, bottom spray coating and side spraying pellet forming, and pellet processing operations and so on
Fluidizing Room has lifting, lowering and cycling structure which can change the angle of fluidizing room, with the easy removal function, washing filter and adjusting spraying gun
Automatic pulse counter blowing material vibrating device, which prevent the block of filter and increase the efficient of air exhausting and production
Adopt the fluid spraying gun that makes the effect of spraying and quality excellent
Filter adopts two structures of filter cloth and metal filter net
Full closed production which conformed to GMP Standard
Main Technical Parameters
LWL(B)-1
Top Spray Product Capacity: 4 kg
Bottom Spray Product Capacity: 3 kg
Bottom Spray Separate : 1
Side Spray Product Capacity: 2 kg
Side Spray Round Disc Diameter : 150 mm
Side Spraying Mouth No : 1
Side Spraying Motor: 0.25 KW
Air Machine System Air Flow nozzle: 10000 m3/h
Air Machine System Pressure difference : 90mbar
Air Machine System Power : 0.75
Public Facility Electric Heating: 2
Public Facility Steam Pressure: 0.4-0.6Mpa
Public Facility Steam Consumption : ——-
Public Facility Compressed Air Pressure : 0.3-0.7 Mpa
Public Facility Compressed Air Consumption : 0.18 m3/h
Working Temperature : Room Temperature to 140 degrees, Adjusting Automatically
Recovery factor of Material : No less than 99%
Product Water Content : The water content of the material after drying is 0.12%
Noise : No more than 75dBA (Fan Separating Treatment)
LWL(B)-30
Top Spray Product Capacity: 120 kg
Bottom Spray Product Capacity: 90 kg
Bottom Spray Separate : 1
Side Spray Product Capacity: 40 kg
Side Spray Round Disc Diameter : 400 mm
Side Spraying Mouth No : 1
Side Spraying Motor: 2.2 KW
Air Machine System Air Flow nozzle: 11800 m3/h
Air Machine System Pressure difference : 90mbar
Air Machine System Power : 7.5/11
Public Facility Electric Heating: 21
Public Facility Steam Pressure: 0.4-0.6Mpa
Public Facility Steam Consumption : 60 kg/h
Public Facility Compressed Air Pressure : 0.3-0.7 Mpa
Public Facility Compressed Air Consumption : 0.9 m3/h
Working Temperature : Room Temperature to 140 degrees, Adjusting Automatically
Recovery factor of Material : No less than 99%
Product Water Content : The water content of the material after drying is 0.12%
Noise : No more than 75dBA (Fan Separating Treatment)
LWL(B)-60
Top Spray Product Capacity: 250 kg
Bottom Spray Product Capacity: 190 kg
Bottom Spray Separate : 1
Side Spray Product Capacity: 80 kg
Side Spray Round Disc Diameter : 550 mm
Side Spraying Mouth No : 2
Side Spraying Motor: 3 KW
Air Machine System Air Flow nozzle: 13000 m3/h
Air Machine System Pressure difference : 90mbar
Air Machine System Power : 11/15
Public Facility Electric Heating: 33
Public Facility Steam Pressure: 0.4-0.6Mpa
Public Facility Steam Consumption : 120 kg/h
Public Facility Compressed Air Pressure : 0.3-0.7 Mpa
Public Facility Compressed Air Consumption : 0.9 m3/h
Working Temperature : Room Temperature to 140 degrees, Adjusting Automatically
Recovery factor of Material : No less than 99%
Product Water Content : The water content of the material after drying is 0.12%
Noise : No more than 75dBA (Fan Separating Treatment)
LWL(B)-120
Top Spray Product Capacity: 450 kg
Bottom Spray Product Capacity: 340 kg
Bottom Spray Separate : 3
Side Spray Product Capacity: 140 kg
Side Spray Round Disc Diameter : 850 mm
Side Spraying Mouth No : 4
Side Spraying Motor: 3 KW
Air Machine System Air Flow nozzle: 14000 m3/h
Air Machine System Pressure difference : 90mbar
Air Machine System Power : 18.5
Public Facility Electric Heating: 42
Public Facility Steam Pressure: 0.4-0.6Mpa
Public Facility Steam Consumption : 140 kg/h
Public Facility Compressed Air Pressure : 0.3-0.7 Mpa
Public Facility Compressed Air Consumption : 0.9 m3/h
Working Temperature : Room Temperature to 140 degrees, Adjusting Automatically
Recovery factor of Material : No less than 99%
Product Water Content : The water content of the material after drying is 0.12%
Noise : No more than 75dBA (Fan Separating Treatment)
LWL(B)-200
Top Spray Product Capacity: 700 kg
Bottom Spray Product Capacity: 550 kg
Bottom Spray Separate : 3
Side Spray Product Capacity: 240 kg
Side Spray Round Disc Diameter : 1100 mm
Side Spraying Mouth No : 4
Side Spraying Motor: 4 KW
Air Machine System Air Flow nozzle: ——
Air Machine System Pressure difference : 90mbar
Air Machine System Power : 22
Public Facility Electric Heating: 70
Public Facility Steam Pressure: 0.4-0.6Mpa
Public Facility Steam Consumption : 180 kg/h
Public Facility Compressed Air Pressure : 0.3-0.7 Mpa
Public Facility Compressed Air Consumption : 1.1 m3/h
Working Temperature : Room Temperature to 140 degrees, Adjusting Automatically
Recovery factor of Material : No less than 99%
Product Water Content : The water content of the material after drying is 0.12%
Noise : No more than 75dBA (Fan Separating Treatment)